Arjun30 - Salient Features

  • Weighs only 800g with battery
  • One-hand-operation
  • Only few keys for user friendly menu navigation
  • High resolution (800 x 480 pixels ) WVGA display
  • Removable Micro SD card up to 32GB
  • USB communication port
  • Auto plotting dynamic DAC
  • On Board DGS/AVG for defect size evaluation
  • Software for AWS D1.1 Sizing
  • Continuous/Dynamic A-Scan and B-Scan recording within the machine (up-to 100 hours in 8 GB Micro SD card)
  • Best for Documentation, Evidence, Analysis and Reporting
  • Real time color coded un-encoded B-Scan along with A-Scan on the screen
  • Square Wave Pulser
Technical Specifications
Test Range 2.5 mm to 10 meter (in steel). Fine mode adjustable in step of 1mm.
Velocity 1000 m/s to 15000 m/s. In Hot Key mode it has 21 pre-set values.Fine mode adjustable in step of 1 m/s.
Delay Up to 3 meter adjustable in 0.01, 0.1 or 1mm step.
Gain 100 dB calibrated gain adjustable in 0.1, 0.5, 1, 2, 6 or 14 dB step.
Rejection 0 to 125% FSH with LED indicator.
Rectification Full wave rectified with filtering.
Frequency 0.5 MHz to 15 MHz (Wideband).
Linearity deviation Vertical: ±3%, Horizontal: ±0.5%.
Test Modes Pulse echo and transmit/receive.
Probe Connectors LEMO Size 00 (2 no’s).
Monitor Dual gate adjustable in 1% of Screen width with Positive/Negative logic,
Gate Expand Gate Expand modes. Expands Range to width of the gate.
A-Scan memory 500 Trace Patterns can be stored, recalled or transferred to PC via USB port.A-Scan trace pattern can be directly stored on SD card or on External USB disk.
Calibration Set-up 50 different calibration set-ups can be Stored and Recalled.
Software ArjnSoft30 Interface software for Data transfer, Analysis, Reporting and Printing.
USB and SD card External USB disk and Micro SD card (up to 32GB) ports provided for data storage.
Display 5 inch Colour Wide VGA LCD/TFT display (800×480 pixel, size 108×64 mm) with higher resolution LCD for better signal representation and better visibility with different colour sets.
Reference A-Scan Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing.
Echo Dynamic Echo Dynamic pattern display.
Dynamic DAC Dynamic DAC curve can be Digitally plotted (Smooth parabolic curve) on screen with selectable additional offset curves from 0 to 14 dB in 0.1 dB selectable steps.DAC curve can be set as flaw monitor gate can be plotted using minimum 2 to maximum 10 points.
DGS